    Acute effects of ventilator hyperinflation with increased inspiratory time on respiratory mechanics: randomized crossover clinical trial

    Rev Bras Ter Intensiva. 2019;31(3):289-295

    Abstract

    Original Articles

    Acute effects of ventilator hyperinflation with increased inspiratory time on respiratory mechanics: randomized crossover clinical trial

    Rev Bras Ter Intensiva. 2019;31(3):289-295

    DOI 10.5935/0103-507X.20190052

    Views1

    ABSTRACT

    Objective:

    To evaluate the effects of ventilator hyperinflation on respiratory mechanics.

    Methods:

    A randomized crossover clinical trial was conducted with 38 mechanically ventilated patients with pulmonary infection. The order of the hyperinflation and control (without changes in the parameters) conditions was randomized. Hyperinflation was performed for 5 minutes in pressure-controlled ventilation mode, with progressive increases of 5cmH2O until a maximum pressure of 35cmH2O was reached, maintaining positive end expiratory pressure. After 35cmH2O was reached, the inspiratory time and respiratory rate were adjusted so that the inspiratory and expiratory flows reached baseline levels. Measurements of static compliance, total resistance and airway resistance, and peak expiratory flow were evaluated before the technique, immediately after the technique and after aspiration. Two-way analysis of variance for repeated measures was used with Tukey’s post hoc test, and p < 0.05 was considered significant.

    Results:

    Ventilator hyperinflation increased static compliance, which remained at the same level after aspiration (46.2 ± 14.8 versus 52.0 ± 14.9 versus 52.3 ± 16.0mL/cmH2O; p < 0.001). There was a transient increase in airway resistance (6.6 ± 3.6 versus 8.0 ± 5.5 versus 6.6 ± 3.5cmH2O/Ls-1; p < 0.001) and a transient reduction in peak expiratory flow (32.0 ± 16.0 versus 29.8 ± 14.8 versus 32.1 ± 15.3Lpm; p <0.05) immediately after the technique; these values returned to pretechnique levels after tracheal aspiration. There were no changes in the control condition, nor were hemodynamic alterations observed.

    Conclusion:

    Ventilator hyperinflation promoted increased compliance associated with a transient increase in airway resistance and peak expiratory flow, with reduction after aspiration.

    See more
    Acute effects of ventilator hyperinflation with increased inspiratory time on respiratory mechanics: randomized crossover clinical trial

Search

Search in:

Article type
article-commentary
brief-report
case-report
correction
editorial
editorial
letter
letter
other
rapid-communication
reply
research-article
research-article
review-article
Session
Articles
Artigo de Revisão de Pediatria
Artigo Original
Artigo Original de Pediatria
Artigo Original Destaque
Artigos de Revisão
Artigos originais
Author's Response
Brief Communication
Case Report
Case Reports
Clinical Report
Comentários
Commentaries
Commentary
Consenso Brasileiro de Monitorização e Suporte Hemodinâmico
Correspondence
Editoriais
Editorial
Editorials
Erratum
Letter to the Editor
Letters to the Editor
Original Article
Original Article – Basic Research
Original Article – Neonatologia
Original Articles
Original Articles – Basic Research
Original Articles – Clinical Research
Relato de Caso
Relatos de Caso
Research Letter
Review
Review Article
Special Article
Special Articles
Viewpoint
Year / Volume
2024; v.36
2023; v.35
2022; v.34
2021; v.33
2020; v.32
2019; v.31
2018; v.30
2017; v.29
2016; v.28
2015; v.27
2014; v.26
2013; v.25
2012; v.24
2011; v.23
2010; v.22
2009; v.21
2008; v.20
2007; v.19
2006; v.18
ISSUE