Search - Critical Care Science (CCS)

You searched for:"Evelim Leal de Freitas Dantas Gomes"

We found (2) results for your search.
  • Original Article

    Does the endotracheal tube insertion depth predicted by formulas in children have a good concordance with the ideal position observed by X-ray?

    Rev Bras Ter Intensiva. 2020;32(2):295-300

    Abstract

    Original Article

    Does the endotracheal tube insertion depth predicted by formulas in children have a good concordance with the ideal position observed by X-ray?

    Rev Bras Ter Intensiva. 2020;32(2):295-300

    DOI 10.5935/0103-507X.20200046

    Views0

    ABSTRACT

    Objective:

    To evaluate the effectiveness of the different formulas for estimating the insertion depth of an endotracheal tube in children.

    Methods:

    This was an observational and cross-sectional study that included children between 29 days and 2 years of age who were hospitalized in a pediatric intensive care unit and mechanically ventilated. The formulas based on height [(height/10) + 5], the inner diameter of the tube (endotracheal tube × 3), and weight (weight + 6) were evaluated to determine which of them showed better concordance with the ideal insertion depth of the endotracheal tube as evaluated by X-ray.

    Results:

    The correlation between the height-based calculation and the ideal depth observed on X-ray was strong, with r = 0.88, p < 0.05, and a concordance correlation coefficient of 0.88; the correlation between the weight-based calculation and depth on X-ray was r = 0.75, p < 0.05, and concordance correlation coefficient 0.43; and the correlation between endotracheal tube diameter-based calculation and depth on X-ray was r = 0.80, p < 0.05, and concordance correlation coefficient 0.78. Lin’s concordance correlation analysis indicated that the measurements showed weak concordance (< 0.90).

    Conclusion:

    The formulas that estimate the insertion depth of the endotracheal tube in children were not accurate and were discordant with the gold-standard method of X-ray evaluation. There is a need for a new method based on anthropometric variables (weight and height) and age that is effective in guiding health professionals of pediatric intensive care units at the time of intubation.

    See more
    Does the endotracheal tube insertion depth predicted by formulas in children have a good concordance with the ideal position observed by X-ray?
  • Original Articles

    Autonomic responses of premature newborns to body position and environmental noise in the neonatal intensive care unit

    Rev Bras Ter Intensiva. 2019;31(3):296-302

    Abstract

    Original Articles

    Autonomic responses of premature newborns to body position and environmental noise in the neonatal intensive care unit

    Rev Bras Ter Intensiva. 2019;31(3):296-302

    DOI 10.5935/0103-507X.20190054

    Views0

    ABSTRACT

    Objective:

    Evaluate the physiological and autonomic nervous system responses of premature newborns to body position and noise in the neonatal intensive care unit.

    Methods:

    A quasi-experimental study. The autonomic nervous system of newborns was evaluated based on heart rate variability when the newborns were exposed to environmental noise and placed in different positions: supine without support, supine with manual restraint and prone.

    Results:

    Fifty premature newborns were evaluated (gestational age: 32.6 ± 2.3 weeks; weight: 1816 ± 493g; and Brazelton sleep/awake level: 3 to 4). A positive correlation was found between environmental noise and sympathetic activity (R = 0.27, p = 0.04). The mean environmental noise was 53 ± 14dB. The heart rate was higher in the supine position than in the manual restraint and prone positions (148.7 ± 21.6, 141.9 ± 16 and 144 ± 13, respectively) (p = 0.001). Sympathetic activity, represented by a low frequency index, was higher in the supine position (p < 0.05) than in the other positions, and parasympathetic activity (high frequency, root mean square of the sum of differences between normal adjacent mean R-R interval and percentage of adjacent iRR that differed by more than 50ms) was higher in the prone position (p < 0.05) than in the other positions. The complexity of the autonomic adjustments (approximate entropy and sample entropy) was lower in the supine position than in the other positions.

    Conclusion:

    The prone position and manual restraint position increased both parasympathetic activity and the complexity of autonomic adjustments in comparison to the supine position, even in the presence of higher environmental noise than the recommended level, which tends to increase sympathetic activity.

    See more
    Autonomic responses of premature newborns to body position and environmental noise in the neonatal intensive care unit

Search

Search in:

Article type
article-commentary
brief-report
case-report
correction
editorial
editorial
letter
letter
other
rapid-communication
reply
research-article
research-article
review-article
Session
Articles
Artigo de Revisão de Pediatria
Artigo Original
Artigo Original de Pediatria
Artigo Original Destaque
Artigos de Revisão
Artigos originais
Author's Response
Brief Communication
Case Report
Case Reports
Clinical Report
Comentários
Commentaries
Commentary
Consenso Brasileiro de Monitorização e Suporte Hemodinâmico
Correspondence
Editoriais
Editorial
Editorials
Erratum
Letter to the Editor
Letters to the Editor
Original Article
Original Article – Basic Research
Original Article – Neonatologia
Original Articles
Original Articles – Basic Research
Original Articles – Clinical Research
Relato de Caso
Relatos de Caso
Research Letter
Review
Review Article
Special Article
Special Articles
Viewpoint
Year / Volume
2024; v.36
2023; v.35
2022; v.34
2021; v.33
2020; v.32
2019; v.31
2018; v.30
2017; v.29
2016; v.28
2015; v.27
2014; v.26
2013; v.25
2012; v.24
2011; v.23
2010; v.22
2009; v.21
2008; v.20
2007; v.19
2006; v.18
ISSUE